Fuel Pump Qualification Testing Support

Provided certification assurance for three fuel pumps across a multi-year aircraft qualification programme.

Eaton required full DO-160 qualification for three revised fuel pumps to support aircraft certification, with schedule and compliance risk across multiple test regimes.

KDC acted as an embedded delivery partner, owning qualification planning, documentation and reporting under a fixed-price, task-driven engagement, with customer and OEM test and documentation review and feedback.

This approach provided regulatory assurance, protected the certification schedule and enabled confident progression to manufacturing and in-service support.

REQUIREMENT

Full qualification required for three new / revised fuel pumps to support aircraft certification

SKILLS & TOOLS

  • Experience in RTCA DO-160 Environmental and Electro-Magnetic Compatibility (EMC) testing
  • Authorised Boeing Test Witnesses

WAY OF WORKING

Contractual Terms

Fixed Price

Agile Sprint Tasking

SQEP Capability Provision

Engagement Model

Offsite, independent task execution

Task-driven SQEP Capability Provision

Resource deployed to customer team

TASKING

  • Compile qualification requirements
  • Write qualification test procedures
  • Write qualification by similarity reports
  • Support testing
  • Write qualification test reports

DELIVERABLES

  • Qualification by similarity reports x3
  • Qualification Test Reports x3

OUTCOME

Test reports delivered to Eaton end customer for 3x fuel pumps over a 2-year program.

Success Stories

See other success stories from our clients.